{"id":338,"date":"2008-02-01T15:10:00","date_gmt":"2008-02-01T07:10:00","guid":{"rendered":"http:\/\/www.akuadi.org\/?p=64"},"modified":"2009-11-14T23:17:54","modified_gmt":"2009-11-14T15:17:54","slug":"sun-modular-datacenter-s20","status":"publish","type":"post","link":"https:\/\/akuadi.org\/life\/blog\/2008\/02\/01\/sun-modular-datacenter-s20\/","title":{"rendered":"Sun Modular Datacenter S20"},"content":{"rendered":"<div class=\"pc0\">\n<div class=\"pc0v0\">Did you all read\/hear about the sun modular system.. thy announced the new product now the <a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/index.jsp\" target=\"_blank\" rel=\"noopener\">Datacenter S20 <\/a><br \/>This is good for big2 company like <a href=\"http:\/\/www.google.com\" target=\"_blank\" rel=\"noopener\">google<\/a>, <a href=\"http:\/\/www.yahoo.com\" target=\"_blank\" rel=\"noopener\">yahoo<\/a>, <a href=\"http:\/\/www.intel.com\" target=\"_blank\" rel=\"noopener\">intel<\/a>&#8230;  they have a alot of data transaction persecond<\/p>\n<p>source: <a href=\"http:\/\/www.sun.com\" target=\"_blank\" rel=\"noopener\">SUN<\/a> <\/p>\n<h3>Key Benefits<\/h3>\n<ul>\n<li>10X faster to deploy vs. traditional datacenter<\/li>\n<li>Reduced capital expenses with incremental expansion<\/li>\n<li>Global deployment capability &amp; flexibility to redeploy as needed<\/li>\n<li>4X higher density per rack vs. typical datacenter<\/li>\n<li>40% lower cooling costs in 1\/8th the space<\/li>\n<\/ul>\n<p><\/p>\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr valign=\"top\">\n<td class=\"col1\" width=\"50%\">\n<div class=\"pc0\">\n<div class=\"pc0v0\">\n<h3>Key Specifications<\/h3>\n<ul>\n<li>Configurable up to 8 racks (19&#8243; w x 30.75&#8243; d payload dimensions)<\/li>\n<li>Can cool up to 25kW per rack<\/li>\n<li> Compatible with Sun or third party gear<\/li>\n<li> -29\u00b0C to 54\u00b0C (-20\u00b0F to 130\u00b0F) operating range<\/li>\n<\/ul><\/div>\n<\/div>\n<p> <!-- END PC0 COMPONENT V.0 -->   <!-- BEGIN G18 COMPONENT V.2 --> <\/td>\n<td class=\"col2\"> <!-- END G18 COMPONENT V.2 -->  <!-- BEGIN PC0 COMPONENT V.0 --> <\/p>\n<div class=\"pc0\">\n<div class=\"pc0v0\">\n<h3>Details<\/h3>\n<ul class=\"bluearrows\">\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor1\" target=\"_blank\" rel=\"noopener\">Dimensions and Weight<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor2\" target=\"_blank\" rel=\"noopener\">Capacity<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor3\" target=\"_blank\" rel=\"noopener\">Power Options<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor4\" target=\"_blank\" rel=\"noopener\">External Network Connections<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor5\" target=\"_blank\" rel=\"noopener\">Environmental<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor6\" target=\"_blank\" rel=\"noopener\">External Water Connectivity<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor7\" target=\"_blank\" rel=\"noopener\">Regulations<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor8\" target=\"_blank\" rel=\"noopener\">Certifications<\/a><\/li>\n<li><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/specifications.jsp#Anchor9\" target=\"_blank\" rel=\"noopener\">Supported Hardware<\/a><\/li>\n<\/ul><\/div>\n<\/div>\n<p> <!-- END PC0 COMPONENT V.4 -->   <!-- BEGIN G18 COMPONENT V.3 --> <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p> <!-- END G18 COMPONENT V.3 -->   <!-- BEGIN PC2 COMPONENT V.0 --> <\/p>\n<div class=\"pc2\">\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor1\"><\/a><\/p>\n<div>Dimensions and Weight<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">Length<\/td>\n<td class=\"dcell\"> 6.06m (20 feet)<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Width<\/td>\n<td class=\"dcell\">2.44m (8 feet)<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Height<\/td>\n<td class=\"dcell\">2.59m (8 feet 6 inches)<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Shipping Weight (no payload)<\/td>\n<td class=\"dcell\"><8,165> <\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Maximum Weight<\/td>\n<td class=\"dcell\"><15,422> <\/tr>\n<\/tbody>\n<\/table><\/div>\n<p> <!-- END PC2 COMPONENT V.0 -->  <!-- BEGIN PC2 COMPONENT V.1 --> <\/p>\n<div class=\"pc2\">\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor2\"><\/a><\/p>\n<div>Capacity<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">Rack Quantity<\/td>\n<td class=\"dcell\">8 racks: 7 for payload and 1 for network and the Sun Modular Datacenter control equipment<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Rack Units (RU)<\/td>\n<td class=\"dcell\"> 40 RU per rack for 320 RU total <\/p>\n<ul>\n<li>280 RU available for IT equipment<\/li>\n<li>25 RU available for network equipment<\/li>\n<li>15 RU reserved for the Sun Modular Datacenter monitoring, management, and control equipment<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Rack Dimensions<\/td>\n<td class=\"dcell\">  EIA\/ANSI (RETMA) standard 19&#8243; EIA RS-310-D  <\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Height (usable)<\/td>\n<td class=\"dcell\">177.9 cm (70 inches)<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Depth (usable)<\/td>\n<td class=\"dcell\">78.1cm (30.75 inches) *Includes cable, bezel, &amp; handle depth<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Width (usable)<\/td>\n<td class=\"dcell\">48.26 cm (19 inches)<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Load capacity per rack<\/td>\n<td class=\"dcell\">862 kg (1900 lb.)<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Power per rack<\/td>\n<td class=\"dcell\">12.5kW standard per rack; 25kW &#8220;high power option&#8221; for seven payload racks<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p> <!-- END PC2 COMPONENT V.1 -->  <!-- BEGIN PC2 COMPONENT V.1 --> <\/p>\n<div class=\"pc2\">\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor3\"><\/a><\/p>\n<div>Power Options<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">Low Voltage Configuration<\/td>\n<td class=\"dcell\"> North America\/Japan<\/p>\n<p>Input Voltage: 110\/190 &#8211; 127\/220 VAC, 3 Phase, 50\/60 Hz<br \/>Internally Distributed Voltage: 110 &#8211; 127 VAC, 1 Phase and 190-220 VAC, 3 Phase, 50\/60 Hz (Internal single phase not accessible)  <\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">High Voltage Configuration<\/td>\n<td class=\"dcell\"> International<\/p>\n<p> Input Voltage: 220\/380 &#8211; 240\/415 VAC, 3 Phase, 50\/60 Hz<br \/>Internally Distributed Voltage: 220-240 VAC, 1 Phase and 220\/380 &#8211; 240\/415 VAC, 3 Phase, 50\/60 Hz (Internal single phase not accessible) <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p> <!-- END PC2 COMPONENT V.1 -->   <!-- BEGIN PC2 COMPONENT V.1 --> <\/p>\n<div class=\"pc2\">\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor4\"><\/a><\/p>\n<div>External Network Connections<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">Two network panels supported (choice of one option for each side)<\/td>\n<td class=\"dcell\">  Network Panel Options: <\/p>\n<ul>\n<li>RJ-45 network panel (8 x RJ-45 connectors)<\/li>\n<li>LC Fibre network panel (8 x LC fibre connectors &#8211; single or multi mode)<\/li>\n<li>RJ-45\/LC Fibre network panel (4 x RJ-45 and 4 x LC fibre &#8211; single or multi mode)<\/li>\n<li>Bulk cable pass-through panel<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p> <!-- END PC2 COMPONENT V.1 -->  <!-- BEGIN PC2 COMPONENT V.1 --> <\/p>\n<div class=\"pc2\">\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor5\"><\/a><\/p>\n<div>Environmental<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">External temperature and humidity deployment range (doors closed)<\/td>\n<td class=\"dcell\">-29\u00b0C to 54\u00b0C (-20\u00b0F to 130\u00b0F), up to 100% humidity<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Internal operating temperature and humidity (doors closed)<\/td>\n<td class=\"dcell\"> 10\u00b0C to 35\u00b0C (50\u00b0F to 95\u00b0F) and 20% to 80% relative humidity (RH), noncondensing <\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Altitude<\/td>\n<td class=\"dcell\">3048 m (10,000 ft) or lower depending on payload maximum<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Noise<\/td>\n<td class=\"dcell\"> 56.0 dBA (external at 2 m)<br \/>78.5 dBA (internal at nominal load)<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p> <!-- END PC2 COMPONENT V.1 -->  <!-- BEGIN PC2 COMPONENT V.1 --> <\/p>\n<div class=\"pc2\">\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor\n6\"><\/a><\/p>\n<div>External Water Connectivity<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">Water Hook-ups (each side)<\/td>\n<td class=\"dcell\">50 mm (2 in.) supply and return<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Water Pressure<\/td>\n<td class=\"dcell\"> 50 PSIG nominal, 80 PSIG maximum. <\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Water Flow and Temperature<\/td>\n<td class=\"dcell\"> 170 to 246 LPM (45 to 65 GPM), 18\u00b0C to 22\u00b0C (64\u00b0F to 71\u00b0F) nominal <\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p> <!-- END PC2 COMPONENT V.1 -->  <!-- BEGIN PC2 COMPONENT V.1 --> <\/p>\n<div class=\"pc2\">\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor7\"><\/a><\/p>\n<div>Regulations (meets or exceeds the following requirements when deployed)<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">Safety<\/td>\n<td class=\"dcell\"> UL 60950-1 (ETL Classification Marking) UL 50, Ed. 11 (NEMA 3R equivalent levels) Russia CB Scheme with national differences CAN\/CSA C22.2 No. 60950-1 EN60950-1 CENELEC EN 60529 (IP-44 levels) <\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">RFI\/EMI<\/td>\n<td class=\"dcell\"> EN55022 (the Sun Modular Datacenter &amp; payload) Payload relevant testing: <\/p>\n<ul>\n<li>CFR47, Part 15, FCC Class A<\/li>\n<li>ICES-003 Class A<\/li>\n<li>VCCI<\/li>\n<li>CNS-13438<\/li>\n<li>AS\/NZS 3548<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">Immunity<\/td>\n<td class=\"dcell\">EN55024<\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<p> <!-- END PC2 COMPONENT V.1 -->  <!-- BEGIN PC2 COMPONENT V.1 -->    <\/p>\n<table border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\">\n<tbody>\n<tr class=\"titlebar\">\n<th colspan=\"2\"><a name=\"Anchor8\"><\/a><\/p>\n<div>Certifications<\/div>\n<\/th>\n<\/tr>\n<tr>\n<td class=\"tcell\">Safety<\/td>\n<td class=\"dcell\">CE Mark, GOST<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">EMC<\/td>\n<td class=\"dcell\">CE Mark, ETL, C-Tick, GOST-R, BSMI, MIC<\/td>\n<\/tr>\n<tr>\n<td class=\"line\" colspan=\"2\">\n<hr \/>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tcell\">ROHS<\/td>\n<td class=\"dcell\">RoHS-compliant (with lead-in solder exemption) for control &amp; management equipment<\/p>\n<p><a href=\"http:\/\/www.sun.com\/products\/sunmd\/s20\/supported_hardware.jsp\" target=\"_blank\" rel=\"noopener\"><span style=\"font-weight: bold; font-style: italic; color: rgb(255, 0, 0);\">Hardware Spec<\/span><\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Did you all read\/hear about the sun modular system.. thy announced the new product now the Datacenter S20 This is good for big2 company like google, yahoo, intel&#8230; they have a alot of data transaction persecond source: SUN Key Benefits 10X faster to deploy vs. traditional datacenter Reduced capital expenses with incremental expansion Global deployment [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[43],"tags":[],"class_list":["post-338","post","type-post","status-publish","format-standard","hentry","category-unix"],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/posts\/338","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/comments?post=338"}],"version-history":[{"count":0,"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/posts\/338\/revisions"}],"wp:attachment":[{"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/media?parent=338"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/categories?post=338"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/akuadi.org\/life\/wp-json\/wp\/v2\/tags?post=338"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}