If your facing the hanging process when run the prtdiag command. Please follow step below..
======================== IO Configuration =========================
IO
Location Type Slot Path Name Model
———– —– —- ——————————————— ————————- ———
MB/PCIE PCIE MB /[email protected]/[email protected]/[email protected]/[email protected]/[email protected]/[email protected] pci-pciexclass,060400
MB/NET0 PCIE MB /p[email protected]/[email protected]/[email protected]/[email protected]/[email protected]/[email protected] network-pciex8086,105e
MB/NET1 PCIE MB /pci@0/[email protected]/[email protected]/[email protected]/[email protected]/[email protected],1 network-pciex8086,105e
MB/NET2 PCIE MB /p[email protected]/[email protected]/[email protected]/[email protected]/[email protected]/[email protected] network-pciex8086,105e
MB/NET3 PCIE MB /pci@0/[email protected]/[email protected]/[email protected]/[email protected]/[email protected],1 network-pciex8086,105e
MB/PCIE PCIE MB /[email protected]/[email protected]/[email protected]/[email protected] scsi-pciex1000,58 LSI,1068E
Environmental Status
Fan sensors: <<<<<<<<<<<<< hanging here:
What is picl:
svc:/system/picl:default platform information and control
# svcs -a |grep picl
online Dec_19 svc:/system/picl:default
# svcadm -v disable svc:/system/picl:default
svc:/system/picl:default disabled.
# svcs -a |grep picl
disabled 23:08:14 svc:/system/picl:default
#wait a minutes before enable the picl back
# svcadm -v enable svc:/system/picl:default
svc:/system/picl:default enabled.
# svcs -a |grep picl
online 23:12:13 svc:/system/picl:default